Victory Reach-In Manuale di Servizio Pagina 35

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 92
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 34
Section 5 Electrical System
5-9
Freezers - Self-Contained - F1 (50/60 Hz)
(Shown in cooling cycle)
For electrical sequence of operation, see page 5-2.
SEE SERIAL PLATE
FOR VOLTAGE
L2 (N)
L1
MAIN
ON/OFF
SWITCH
TB30
TB30
TB30
TB31
TB31
TB31
TB31
(69)
NO
NC
TEMPERATURE CONTROL
CONDENSER
FAN
OVERLOAD
N
R
S
RUN CAPACITOR
RR
TO TEMP CONTROL
SEE ABOVE
(46)
OVERLOAD
COMPRESSOR
(76)
S
5
(51)
START CAPACITOR
(80)
S
M
L
F1 (50HZ) COMPRESSOR
WIRING ONLY
(74)
START RELAY
TB30
TB31
(68)
(59)
(56)
(60)
(70)
DRAIN LINE HEATER
DOOR HEATER
(73) (65)
TB36
(72)
TB32
(66)
(55) (54)
EVAPORATOR
FAN MOTORS
CABINET
LIGHT
DOOR LIGHT/FAN SWITCH
(71)
COOLING
DEFROST
3
1
2
4
X
TB33
TB35
DEFROST HEATER
DEFROST END AND FAN
DELAY THERMOSTAT
1
2
3
(57)
(44)
BLUE
RED
C
BLACK
TB35
(78)
(78)
(77)
S
2
1
COMPRESSOR
START RELAY
(74)
(75)
(79) (81)
START CAPACITOR
R
S
C
(52)
(75)
TB35
(50)
TIMER
RELEASE
SOLENOID
SV1525
(49)
Vedere la pagina 34