Component Replacement Procedures
Accessing Evaporator Assembly
1. Disconnect electrical power to the reach-in.
2. Remove the two screws on the drain tube.
3. Lift up on the refrigeration section until the evaporator drain clears the drain tube.
4. Turn the drain tube to the left.
5. Loosen the thumb screws on the front of the evaporator drain pan. Lower the drain pan.
Figure 8-1: Accessing Evaporator Assembly
1. LOOSEN SCREWS
2. LIFT REFRIGERATOR
SYSTEM UP