Section 7 Diagnostics
7-11
Diagnosing Compressor and Start Components Electrically
General
Perform the following tests, in sequence,
using a quality calibrated volt-meter.
Important
Refer to the proper wiring diagram during
each test.
1. Verify that the electric power to the
reach-in at compressor start-up is +/- 10%
of the line voltage rating.
2. Verify that the following control
components are in the closed position if
the compressor does not try to start:
Main ON/OFF switch
High pressure cutout control
Temperature control
Relay
Defrost time clock contact #4 (freezer
only)
WARNING
Disconnect electric power to the reach-in and
the electric service switch box before
proceeding with the following steps.
External Overload Check
Check the continuity of the external overload
protector. If the compressor has an internal
overload protector, skip this test.
1. Disconnect the overload wires from other
components.
2. Check the continuity of the overload
protector:
Results of Check Action
Continuity Overload protector is OK
No continuity
Allow the compressor to
reach room temperature
and check again
No continuity
at room
temperature
Replace the
overload protector
Start Relay Check
CURRENT RELAY
1. Disconnect the wires from the start relay.
If the relay must be moved, keep it
upright.
2. Check continuity at the contact terminals.
Refer to wiring diagram for terminal
identification.
Results of Check Action
Continuity Replace the relay
No continuity Relay is OK
3. Check continuity at the relay coil
terminals. Refer to wiring diagram for
terminal identification.
Results of Check Action
Continuity Relay is OK
No continuity Replace the relay
POTENTIAL RELAY
1. Disconnect the wires from the start relay.
2. Check continuity between terminals 1 and
2. (Normally open)
Results of Check Action
Continuity Replace the relay
No continuity Relay is OK
3. Check the continuity between terminals 5
and 1. (Coil)
Results of Check Action
Continuity Relay is OK
No continuity Replace the relay