Section 7Diagnostics
7-6
Light/Fan Switch(es)
FUNCTION for refrigerators (R1, R2, R3,
RS1, RS2, RS3, RR1, RR2, RR3)
Turns the interior cabinet light on as the
reach-in door is opened.
FUNCTION for freezers (F1, F2, F3, FS1,
FS2, FS3, FR1, FR2, FR3)
Turns the evaporator fans off and the interior
cabinet light on as the reach-in door is
opened.
SPECIFICATIONS
Push button switch (2 circuit)
CHECK PROCEDURES
1. Check for proper line voltage (+/- 10%).
2. Inspect the switch for proper wiring.
3. Inspect the terminals for clean, tight
connections.
4. Check across the switch terminals with a
voltmeter. Replace the switch if you do
not obtain the results below:
Door
Position
N.O.
Contacts
N.C.
Contacts
Closed 0 line
Open line 0
SELF-CONTAINED REFRIGERATOR
FAN MOTOR WIRING CHANGE
The evaporator fan motor(s) on the units
listed below must be modified.
The evaporator fan(s) must run continuously,
including while the door is open. Otherwise,
frost will form on the evaporator coil.
For models BEFORE serial number:
Model Serial Number
RS1 931080000
RS2 930580000
RS3 930380000
1. Unplug the fan motor wire from terminal
board connection #8.
2. Plug it into terminal board connection #1.
For models AFTER serial number:
Model Serial Number
RS1
RS2 931080000
RS3
1. Disconnect evaporator fan lead #65 from
the terminal board and plug it in to
connection TB30.
2. Disconnect evaporator fan lead #66 from
the terminal board and plug it in to
connection TB31.