Section 8Component Replacement Procedures
8-2
Evaporator Fan(s)
1. Disconnect electrical power to the reach-in.
2. Lower the evaporator drain pan (see page 8-1).
3. Unplug the fan motor.
4. Remove the evaporator fan bracket screws.
5. Pull the fan blade off the motor shaft and remove the fan motor from the bracket.
Figure 8-2: Evaporator Fan(s)
FAN MOTOR
SV1246
TO BE DISCONNECTED
BEFORE DISASSEMBLY
BRACKET
FAN BLADE
EVAPORATOR
HOUSING
EVAPORATOR
FAN GAURD