Section 8 Component Replacement Procedures
8-11
TENSION ADJUSTMENT
Use hand tools only for this procedure.
1. Completely release the door tension by
turning the door tension adjustment screw
clockwise.
2. Open the door approximately 2-3 inches.
3. Without touching the door, slowly turn the
door tension adjustment screw clockwise
until the door closes.
4. Turn the screw two more complete
revolutions.
NOTE: This is the factory tension setting. If
desired, you may slightly increase or decrease
the tension setting.
DOOR SAG ADJUSTMENT
Use hand tools only for this procedure.
Important
The reach-in cabinet must be level before
beginning the adjustment.
Figure 8-14: Door Sag Adjustment
Turn the door sag adjustment screw clockwise
to increase or counterclockwise to decrease
dimension B to visually match dimension A.
NOTE: Dimension A is not adjustable.
DOOR REMOVAL
WARNING
To prevent personal injury and/or cabinet
damage, perform this procedure with two
people, each capable of lifting 75 lb. (34 kg).
1. Release the door tension by turning the
door tension adjustment screw counter-
clockwise.
2. Use needle nose pliers to remove the
safety snap ring from the top pin shaft.
3. Use a standard screwdriver to carefully
pry the outer shaft retainer from the
torquemaster.
4. Lift the door up and out of the
torquemaster. Do not lower the door yet.
5. Align the hold-open arm stud on the door
with the key hole on the hold-open arm.
Disengage the door from the hold-open
arm.
6. Lower the door to disengage it from the
top hinge bracket pin.
SV1502
DISTANCE
“B”
DISTANCE “A”
SAFETY
SNAP RING