Section 7Diagnostics
7-2
Symptom Possible Cause Corrective Action
Cabinet does not
maintain proper
temperature
Temperature control problem
Control setting is incorrect
Control is defective
Set the control to the
desired setting
Check the control, replace if
defective
Condenser coil is dirty Clean the condenser
(Refrigerators Only)
(Refrigerators Only)
(Freezers Only)
(Freezers Only)
Evaporator coil is frozen
Air flow is restricted
Refrigerant charge is low
Vacuum relief is leaking
Evaporator drain line is not
trapped/no water in trap
Evaporator fan motor is not
running
Door is open/gasket is not
sealing properly
Cap tube is incorrectly
positioned
Cap tube is restricted
Insufficient number of defrost
settings
Calrod defrost heater is not
energizing
Arrange product for proper
interior air flow, check the
evaporator coil for debris
Find and repair any leaks,
replace the drier, evacuate
and recharge the system
Check for leaks, repair or
replace as necessary
Check the trap
Check:
fan motor
light/fan switch
automatic defrost time
clock (freezers only)
defrost end/fan delay
thermostat (freezers only)
Close door, repair or replace
gasket as necessary
Reposition the cap tube
Check the tube, repair or
replace as necessary
Defrost the evaporator coil,
then add another defrost
cycle pin to the automatic
defrost time clock
Check the automatic
defrost and the calrod
heater
Refrigeration problem Refer to Refrigeration
Specifications on page 6-5