Section 6 Refrigeration System
6-5
Refrigeration Specifications
Self-Contained Refrigerators Using R-134a
No Load (empty cabinet) / Door Heaters On /No Door Openings
MODEL R1 R2 R3
Ambient Temperature
Around Cabinet
50°F
10°C
100°F
37.8°C
50°F
10°C
100°F
37.8°C
50°F
10°C
100°F
37.8°C
Temperature Control
Setting
3.0 3.0 3.0 3.0 3.0 3.0
% Run Time:
Solid Door
Glass Door
20%
24%
56%
61%
27%
31%
55%
69%
24%
30%
55%
69%
Average Interior
Cabinet Temperature
38°F
3.3°C
38°F
3.3°C
38°F
3.3°C
38°F
3.3°C
38°F
3.3°C
38°F
3.3°C
Suction Pressure:
Cut-in (psig)
Cut-out (psig)
35
10
35
15
38
2
38
15
35
8
35
15
Discharge Pressure
(psig)
(Last 1/3 of cycle)
65-70 160-175 65-75 180-195 80-90 180-195
Heat of Rejection
Air Conditioning
Peak
2500
3100
3800
4700
6100
7500
Compressor
1/4 HP 1/3 HP 1/2 HP
Refrigerant Charge
8 oz. 11 oz. 13 oz.
Self-Contained Refrigerators Using R-402B (HP81)
No Load (empty cabinet) / Door Heaters On /No Door Openings
MODEL RS1 RS2 RS3
Ambient Temperature
Around Cabinet
60°F
15.6°C
100°F
37.8°C
60°F
15.6°C
100°F
37.8°C
60°F
15.6°C
100°F
37.8°C
Temperature Control
Setting
3.5 3.5 3.5 3.5 3.5 3.5
Maximum % Run Time:
19% 53% 29% 66% 27% 60%
Average Interior
Cabinet Temperature
38°F
3.3°C
38°F
3.3°C
38°F
3.3°C
38°F
3.3°C
38°F
3.3°C
38°F
3.3°C
Suction Pressure:
Cut-in (psig)
Cut-out (psig)
66
29
88
52
70
36
91
52
75
28
76
41
Discharge Pressure
(psig)
(Last 1/3 of cycle)
180-200 340-360 180-200 340-360 195-215 295-320
Heat of Rejection
Air Conditioning
Peak
3100
3700
3600
4300
4500
5800
Compressor
1/4 HP 1/3 HP 1/2 HP
Refrigerant Charge
10 oz. 10.5 oz. 14.5 oz.